KRYPTON LITELux Simulation Report
WORKING PLANE ANALYSIS
2D Lux Distribution
12.0 m
8.0 m
Top view · Working plane 0.76 m · Identical luminaires use identical symmetrical spread
0125250375500625750875Lux
RECOMMENDED LIGHTING LAYOUT
8 luminaires in a complete 2 × 4 grid.
Every row and column is complete—no uneven final row.
CALCULATION SUMMARY
Design overview.
- Room area
- 96 m²
- Mounting above working plane
- 2.84 m
- Estimated average
- 576 lx
- Minimum / maximum
- 91 / 1,019 lx
- Uniformity (minimum ÷ average)
- 0.16
- Design status
- Target achieved
Important: This online tool provides a preliminary lighting estimate, not a certified DIALux calculation. Actual results depend on luminaire photometry, surface reflectance, room geometry, obstructions, installation conditions and applicable standards. Contact Krypton Lite for a project-specific lighting design.